HG series multi-function standard source and calibrator
-
MGY/DO30 Series Calibrator/Trimeter Calibrator
-
Three-phase/single-phase electric energy meter calibration device
-
Insulation resistance meter (megger) calibration device
-
High voltage/ground resistor (device/box)
-
AC and DC high current standard source/welding machine calibrator
-
Clamp ammeter calibration device
-
GZC series petrochemical measurement and control instruments
-
HGZW series dyeing, weaving and weft trimming machine
-
other products
-
DO30 series three-meter/multimeter calibrator
HG-3D handheld single-phase field calibrator
The handheld single-phase electric energy performance calibrator is designed for on-site online testing of the accuracy and function of single-phase electric energy meters. It can measure electric energy, power, current, voltage, power factor, meter error and constant calibration without power interruption or disconnection. It can save the data of 2000 meters. At the same time, it has data query and management functions.
- Product description
-
The handheld single-phase electric energy performance calibrator is designed for on-site online testing of the accuracy and function of single-phase electric energy meters. It can measure electric energy, power, current, voltage, power factor, meter error and constant calibration without power interruption or disconnection. It can save the data of 2000 meters. At the same time, it has data query and management functions.
The instrument uses a 32-bit ARM embedded system, graphically displays the menu, and completes precision adjustment through buttons, thereby improving reliability and stability. This instrument is compact and lightweight, has complete functions, is easy to use, and has beautiful appearance. It is an ideal instrument for online detection of single-phase electric energy meters.
Technical performanceWorking power: 100-270 (AC)
Voltage measurement: Level 0.2 (110V-270V)
Current measurement: wide range current clamp: 100AAccuracy 0.2 level
Electric energy measurement: wide range current clamp 100A
Accuracy: 0.3/0.5 level
Power factor: 0.01 (0.4000~1.0000)
Configurable dummy load: current 5A/2A (optional)
Harmonic test: 1~32nd
CT transformation ratio test: The CT transformation ratio test can be carried out through a current clamp meter.
Constant calibration test can be performed on the meter.The instrument can store at least 2,000 sets of table data.
11. The verification data can be managed through the data line. (optional)
12. Instrument constant: 800
Weight: 0.5Kg
Volume: 205mm×100mm×35mm
Keywords:- 电流
- 仪器
- 精度
- 测量
- 数据
- 常数
- 功能
- 进行
- 测试