DO30 series three-meter/multimeter calibrator
HG112 low resistance meter tester
HG112 low resistance meter tester is a standard instrument for measuring, calibrating and verifying DC low resistance testers (digital bridge, microohmmeter, etc.). The HG112 low resistance meter tester has ten ranges: ×103Ω, ×102Ω, ×101Ω, ×100Ω, ×10-1Ω, ×10-2Ω, ×10-3Ω, ×10-4Ω, ×10-5Ω, ×10- 6Ω. Each range has 20 resistance values. The ×10-2Ω, ×10-3Ω, ×10-4Ω, ×10-5Ω, ×10-6Ω range is a dedicated DC analog resistance box, which uses a resistor network line and provides (0. 01mΩ~1μΩ) DC analog equivalent resistance.
- Product description
-

HG112 low resistance meter tester is a standard instrument for measuring, calibrating and verifying DC low resistance testers (digital bridge, microohmmeter, etc.). The HG112 low resistance meter tester has ten ranges: ×103Ω, ×102Ω, ×101Ω, ×100Ω, ×10-1Ω, ×10-2Ω, ×10-3Ω, ×10-4Ω, ×10-5Ω, ×10- 6Ω. Each range has 20 resistance values. The ×10-2Ω, ×10-3Ω, ×10-4Ω, ×10-5Ω, ×10-6Ω range is a dedicated DC analog resistance box, which uses a resistor network line and provides (0. 01mΩ~1μΩ) DC analog equivalent resistance.
This calibrator can calibrate DC resistance testers (digital bridge, microohmmeter) with a range of (1 μΩ~20kΩ) and an accuracy of ≤5×10-4.
2. Technical indicators
Technical indicators: ≤1×10-4~1×10-2
Calibration temperature: 20℃±1℃, relative humidity: 40%~60%
Operating temperature: 20℃±5℃, relative humidity: 25%~75%
Size: 490×300×220
Basic parameters: The basic parameters of each range of the calibrator are shown in the table below:Measuring range Adjustment range Step disc(Ω) level of accuracy Working power supply Reference value nominal value limit value 1µΩ
(0~ 20) µΩ
1µΩ
1
15A
20A
25A
10µΩ
(0~200) µΩ
10µΩ
0.1
13A
15A
17A
100µΩ
(0~ 2) mΩ
100µΩ
0.1
7A
10A
14A
1mΩ
(0~ 20) mΩ
1mΩ
0.02
3A
7A
10A
10mΩ
(0~200) mΩ
10mΩ
0.01
2A
4.5A
5A
100mΩ
(0~ 2) Ω
100mΩ
0.01
700mA
1A
1.4A
1Ω
(0~ 20) Ω
1Ω
0.01
200mA
200mA
450mA
10Ω
(0~200) Ω
10Ω
0.01
70mA
100mA
140mA
100Ω
(0~ 2) kΩ
100Ω
0.01
20mA
20mA
45mA
1kΩ
(0~ 20) kΩ
1KΩ
0.01
7mA
2mA
14mA
Used power: Low-range resistance disks ×10-2Ω, ×10-3Ω, ×10-4Ω, ×10-5Ω, ×10-6Ω are composed of resistor networks. The power of each plate should be different.
Low-range resistance plate × 10-2Ω, rated current ≤ 2A
Low range resistance plate ×10-3Ω, rated current ≤7A
Low range resistance disk ×10-4Ω, rated current ≤10A
Low range resistance disk ×10-5Ω, rated current ≤13A
Low range resistance disk ×10-6Ω, rated current ≤15A
Note: Please do not exceed the maximum current during use, and only for a short period of time, otherwise the resistor will be burned out.
6. Insulation resistance: Under nominal conditions, the insulation resistance between the metal shell and the terminals of the instrument is not less than 500MΩ, and the test voltage is 500V.
7. Withstand voltage test: Under nominal conditions, the instrument should withstand a 50Hz sine wave alternating current voltage of 1000V between the metal shell and the terminals, and the test lasts for 1 minute without breakdown or discharge.