HG series multi-function standard source and calibrator
-
MGY/DO30 Series Calibrator/Trimeter Calibrator
-
Three-phase/single-phase electric energy meter calibration device
-
Insulation resistance meter (megger) calibration device
-
High voltage/ground resistor (device/box)
-
AC and DC high current standard source/welding machine calibrator
-
Clamp ammeter calibration device
-
GZC series petrochemical measurement and control instruments
-
HGZW series dyeing, weaving and weft trimming machine
-
other products
-
DO30 series three-meter/multimeter calibrator
JD-1B ground resistance meter calibration device
The JD-1B ground resistance meter calibration device is a standard instrument for calibrating ground resistance meters. It fully complies with the requirements of JJG366-2004 for standard instruments. It can calibrate analog and digital ground resistance meters of various accuracy levels and models. It shall not be used for the verification of ground conduction resistance meter (working current is AC25A). It can be used as a resistance box with a starting resistance of 10mΩ and a resolution of 1mΩ.
- Product description
-
1 Overview
JD-1B ground resistance meter calibration device is a safety instrument produced based on the principle of potential compensation. It is simple to operate and portable, and is widely used to measure the ground resistance of single grounding bodies and centralized grounding bodies. The measurement of ground resistance is an important measure to monitor the quality of grounding and ensure the safety of electricity.
The national calibration regulations for ground resistance meters (instruments) are JJG366-2004 Calibration Regulations for Ground Resistance Meters.
The JD-1B ground resistance meter calibration device is a standard instrument for calibrating ground resistance meters. It fully complies with the requirements of JJG366-2004 for standard instruments. It can calibrate analog and digital ground resistance meters of various accuracy levels and models. It shall not be used for the verification of ground conduction resistance meter (working current is AC25A). It can be used as a resistance box with a starting resistance of 10mΩ and a resolution of 1mΩ.
2. Main technical indicators:2.1 Resistance output range: 0.010Ω~11111.110Ω; minimum resolution: 1mΩ.
2.2 Analog ground resistance rE (standard resistor)
Resistance (Ω)
×103
×102
×101
×100
×10-1
×10-2
×10-3
power, current
0.25W
0.25W
0.25W
0.25W
0.5A
0.5A
0.5A
Accuracy(%)
0.1
0.1
0.1
0.1
0.5
5
10
2.3 Simulate auxiliary ground resistance rP, rC (auxiliary ground resistance)
Resistance (Ω)
0
500
1000
2000
5000
Accuracy(%)
<0.1Ω
2.0
2.0
2.0
2.0
power
rP 0.5W rC 2W
2.4 Usage environment: temperature 20℃±5℃; relative humidity 40%~75%
2.5 Weight<3kg
2.6 Volume 370mm×265×140mm