NEWS

Troubleshooting methods for electric energy meter field calibrator


                       

Various faults may also occur when the electric energy meter field calibrator is used. Today we will summarize the troubleshooting methods for the electric energy meter calibrator during measurement.

1. When measuring parameters, if the displayed value is very different from the actual value, you should check whether the input voltage and current range are consistent with the actual value.

2. When measuring parameters, if the displayed reading is unstable, you should check whether there is voltage input. In the absence of voltage input, the displayed reading will be unstable when measuring current. When there is voltage input, if the displayed reading is unstable, it means the load is unstable.

3. When calibrating the meter, if the error value is very large, there are several possible reasons:

A. The wiring is wrong, the phase voltage and phase current do not correspond one to one, or the power of a certain phase is negative.

  B. The photoelectric sampler incorrectly samples (ie, oversamples or undersamples). At this time, the position or sensitivity of the photoelectric sampler needs to be readjusted.

C. The current input mode setting is incorrect or the three-phase three-wire or three-phase four-wire mode is incorrect.

D. The sampling current caused by the dirty core end face of the clamp-type current transformer is too small.

E. The core end face of the clamp-type current transformer is not completely closed.

F. The electric meter constant to be calibrated is entered incorrectly.

G. The variable ratio of the calibrated measuring device is entered incorrectly.

H. The on-site load fluctuates too much, or there is strong electromagnetic interference.

 

 

For more information on how to use the calibrator and troubleshooting methods, pay attention to Huaguang Electronic Instruments!

 

 

Related News


[Main product] Multifunctional precision calibrator series

Huaguang Technology is changing with each passing day: DO30 series---HG series--MGY series, constantly upgraded!


[Huaguang] Fully automatic image rapid measurement system for all-round measurement

Fully automatic image rapid measurement system fully launched


[Huaguang] Share metrology results to promote industrial development---2023 National Industrial Metrology Conference and National Industrial Metrology Testing Alliance Founding Conference

The 2023 National Industrial Metrology Conference and the Founding Conference of the National Industrial Metrology Testing Alliance with the theme of "Sharing Measurement Results to Promote Industrial Development" was held in Weifang City, Shandong Province. Weifang will seriously learn from advanced experience, empower measurement with science and technology, promote development with measurement, and continue to Consolidate the “foundation” for high-quality development. I hope that everyone will continue to care about, support and empower Weifang, and work together to achieve win-win results in expanding government-enterprise cooperation, deepening central-local cooperation, and intensifying industry-university-research cooperation, so as to create a better future together.


[Huaguang] Characteristics and applications of multi-function calibrator

The multi-function calibrator is suitable for calibrating, calibrating and repairing digital three-way meters and various pointer AC and DC voltage and ammeters. It can also be used as a high-stability test power supply to calibrate current and voltmeters in conjunction with high-grade standard meters.


[Information] The first national standard launch meeting in the field of machine-readable standards was held in Beijing

On August 29, 2023, the working group launch meeting of the "Machine Readable Standard Capability Level Model", the first national standard in the field of machine readable standards, was held in Beijing


【Huaguang】 Young scholar, it’s time for school to start again

Weifang Huaguang Electronics wishes all students to be confident and conscientious in their future study and life, not to be afraid of difficulties or setbacks, and to thrive through continuous efforts.

Multi-line text content element

HTML language content can be parsed after rich text content is bound to data