DO30-VI type AC multi-function calibrator


DO30-VI AC multifunctional calibrator (improved type) is suitable for calibrating and inspecting various AC current, voltage, frequency, phase, power and power factor meters below level 0.5. It can also be used as a high-stability test power supply to calibrate AC current, voltage, and power meters above level 0.2 in conjunction with high-level standard tables. Equipped with a standard test coil (optional), it can calibrate AC clamp ammeters (0~1000A) below level 1.

  • Product description
  • DO30-VI AC multifunctional calibrator (improved type) is suitable for calibrating and inspecting various AC current, voltage, frequency, phase, power and power factor meters below level 0.5. It can also be used as a high-stability test power supply to calibrate AC current, voltage, and power meters above level 0.2 in conjunction with high-level standard tables. Equipped with a standard test coil (optional), it can calibrate AC clamp ammeters (0~1000A) below level 1.

    Main technical performance parameters of D030-VI AC multi-function calibrator
    This instrument uses a 5½-digit VFD digital display to display the output, and displays various parameters such as V, I, P, F, PF, and φ on the same screen;
    Power consumption: AC power voltage 220V±10%, frequency 50Hz±1Hz, maximum power consumption less than 300VA;
    The output voltage, current, power range and accuracy are shown in the table
    Frequency measurement range: 25~3kHz; Power factor range: 0~±1; Phase range: 0~360°;
    Power measurement range: 0~100kw, resolution 1μw.
    Distortion less than 0.5%
    Output phase accuracy: ±0.2℃ (after zero calibration)
    Output frequency accuracy: ±0.02Hz
    Working hours: continuous
    Stability: voltage and current are less than 0.01% of full scale for 3 minutes
    Power is less than 0.02% of full scale/3 minutes
    Additional shooting affects 0.005%
    Overall dimensions: w×d×h 480×480×180(mm)
    Weight: 20kg

    Technical Data Sheet:

    Output items Output range maximum output Accuracy
    AC and DC voltage 0~1V~2V~5V~10V 800mA Voltage:±(0.03%RD+0.02%FS)
    0~20V~50V 500mA current:±(0.03%RD+0.02%FS)
    0~75V~150V 200mA power:±(0.07%RD+0.03%FS)
    0~300V~600V 80mA Power factor (PF):
    0~1000V 40mA ±0.001(PF:0~±0.8)
    AC and DC current 0~10~20~50~200mA 3V~40V ±0.0005(PF:-0.8~-1+0.8~+1)
    0~1~2~5~10~25A 2V~20V ±0.0001(PF:±1)
    0~50~100A 1V  
    Note: (1) When the working environment temperature exceeds 23℃±2℃, for every 10℃ change, the additional error is less than the basic error of the range.
    (2) The phase angle factor index is not assessed for 20mA and below, and the power factor assessment range is ±0.5~±1